{"product_id":"stromerzeuger-genmac-strong-rent-g30dss-m5-ma-qfip-dguv","title":"Power Generator GENMAC STRONG-RENT G30DSS-M5 MA QFIP-DGUV","description":"\u003ch2\u003eGENMAC STRONG-RENT G30DSS-M5 MA QFIP-DGUV – 30 kVA Diesel Generator in accordance with DGUV 203-032\u003c\/h2\u003e\n\n\u003cp\u003eThe \u003cb\u003eGENMAC STRONG-RENT G30DSS-M5 MA QFIP-DGUV\u003c\/b\u003e is a sound-insulated diesel generator for mobile power supply on construction sites, assembly areas, events, and in professional rental operations. With a continuous output of \u003cb\u003e30 kVA or 24 kW\u003c\/b\u003e, the unit reliably supplies machines, lighting, event technology, construction site distributors, and other electrical consumers with 400\/230 V.\u003c\/p\u003e\n\n\u003cp\u003eThe specially designed switchgear meets the requirements of \u003cb\u003eDGUV Information 203-032\u003c\/b\u003e for the selection and operation of power generators on construction and assembly sites. This makes the GENMAC G30DSS-M5 particularly suitable for applications where, in addition to performance and mobility, a high level of electrical safety is also required.\u003c\/p\u003e\n\n\u003ch3\u003eDGUV-203-032 Compliant Power Supply\u003c\/h3\u003e\n\n\u003cp\u003eIn the DGUV version, the generator operates as an \u003cb\u003eIT system with an ungrounded star point\u003c\/b\u003e. An insulation monitoring device continuously checks the insulation resistance of the connected circuit to earth. The 63-A socket or the fixed connection is protected by this insulation monitoring.\u003c\/p\u003e\n\n\u003cp\u003eThe other sockets are equipped with \u003cb\u003etype B all-current sensitive residual current protective devices with 30 mA\u003c\/b\u003e. These also detect smooth DC fault currents and are therefore suitable for modern consumers with frequency converters, rectifiers, switched-mode power supplies, or electronic power controls. This includes, for example, construction cranes, pumps, chargers, lighting technology, event technology, and various electrically controlled machines.\u003c\/p\u003e\n\n\u003ch3\u003e30 kVA Power for Construction Sites and Events\u003c\/h3\u003e\n\n\u003cp\u003eThe unit delivers a continuous output of \u003cb\u003e30 kVA or 24 kW PRP\u003c\/b\u003e. For emergency power operation, up to \u003cb\u003e32 kVA or 25.6 kW LTP\u003c\/b\u003e are available. Both three-phase consumers with 400 V and single-phase consumers with 230 V can be supplied via the connection panel.\u003c\/p\u003e\n\n\u003cp\u003eTypical applications include:\u003c\/p\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003eConstruction sites and assembly areas\u003c\/li\u003e\n\n\t\u003cli\u003eConstruction containers and construction site lighting\u003c\/li\u003e\n\n\t\u003cli\u003ePumps, compressors, and power tools\u003c\/li\u003e\n\n\t\u003cli\u003eEvent, stage, and sound technology\u003c\/li\u003e\n\n\t\u003cli\u003eCatering, cooling, and mobile gastronomy\u003c\/li\u003e\n\n\t\u003cli\u003eMunicipal uses and temporary infrastructure\u003c\/li\u003e\n\n\t\u003cli\u003eRental and changing deployment locations\u003c\/li\u003e\n\n\t\u003cli\u003eMobile backup and emergency power supply\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\n\u003ch3\u003eLow-Emission Stage V Diesel Engine\u003c\/h3\u003e\n\n\u003cp\u003eThe GENMAC STRONG-RENT G30DSS-M5 is powered by a water-cooled \u003cb\u003eHyundai D18 diesel engine\u003c\/b\u003e with three cylinders, turbocharging, and intercooling. The electronically controlled engine meets the \u003cb\u003eEU Stage V\u003c\/b\u003e emission standard and is designed for economical continuous operation at 1,500 rpm.\u003c\/p\u003e\n\n\u003cp\u003eConsumption depends on the load and is approximately:\u003c\/p\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e2.2 l\/h at 25% load\u003c\/li\u003e\n\n\t\u003cli\u003e3.8 l\/h at 50% load\u003c\/li\u003e\n\n\t\u003cli\u003e5.6 l\/h at 75% load\u003c\/li\u003e\n\n\t\u003cli\u003e7.4 l\/h at 100% load\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\n\u003cp\u003eThe integrated 100-liter tank allows for an operating time of approximately \u003cb\u003e18 hours\u003c\/b\u003e at 75 percent load. This means the unit can be operated for an entire shift or event without needing to refuel in between.\u003c\/p\u003e\n\n\u003ch3\u003eStable Voltage thanks to Stamford Synchronous Generator\u003c\/h3\u003e\n\n\u003cp\u003eThe Stamford generator with automatic voltage regulation ensures a constant output voltage. The regulation accuracy is approximately ±1 percent. This makes the generator suitable not only for robust construction machinery, but also for more sensitive consumers, controls, lighting systems, and electronic devices.\u003c\/p\u003e\n\n\u003cp\u003eControl is handled by a \u003cb\u003eComAp AMF25\u003c\/b\u003e. The control panel displays, among other things, voltage, frequency, current, active power, apparent power, power factor, operating hours, and fuel level.\u003c\/p\u003e\n\n\u003cp\u003eMonitoring includes, among other things:\u003c\/p\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003eOverload\u003c\/li\u003e\n\n\t\u003cli\u003eLow oil pressure\u003c\/li\u003e\n\n\t\u003cli\u003eHigh coolant temperature\u003c\/li\u003e\n\n\t\u003cli\u003eLow fuel level\u003c\/li\u003e\n\n\t\u003cli\u003eOverspeed\u003c\/li\u003e\n\n\t\u003cli\u003eBattery charging fault\u003c\/li\u003e\n\n\t\u003cli\u003eEngine and generator operating values\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\n\u003cp\u003eAn emergency stop button and an audible alarm complete the safety equipment.\u003c\/p\u003e\n\n\u003ch3\u003eSoundproofed and Weatherproof Housing\u003c\/h3\u003e\n\n\u003cp\u003eThe robust STRONG-RENT housing was developed for frequently changing deployment locations and rental operations. The galvanized and coated steel construction protects the engine, generator, and control system from weather influences and mechanical stress.\u003c\/p\u003e\n\n\u003cp\u003eThe 35 mm thick sound insulation reduces the sound pressure level to approximately \u003cb\u003e65 dB(A) at seven meters\u003c\/b\u003e. This makes the G30DSS-M5 suitable for events, inner-city construction sites, and other noise-sensitive areas.\u003c\/p\u003e\n\n\u003cp\u003eFour large, lockable maintenance doors provide good access to the engine and generator. Forklift pockets in the base frame and a central crane hook facilitate loading and moving the unit.\u003c\/p\u003e\n\n\u003ch3\u003eDesigned for Mobile Use and Rental\u003c\/h3\u003e\n\n\u003cp\u003eThe welded steel base frame features robust vibration dampers and an integrated drip tray for leaking operating fluids. The protected cable connection area and the clearly arranged control panel facilitate daily handling.\u003c\/p\u003e\n\n\u003cp\u003eWeighing around \u003cb\u003e880 kg\u003c\/b\u003e, the unit can be transported by forklift or crane. Its compact design also allows for space-saving setup behind stages, next to construction containers, or within cordoned-off construction site areas.\u003c\/p\u003e\n\n\u003ch3\u003eTechnical Data\u003c\/h3\u003e\n\n\u003cdiv\u003e\n\n\u003cdiv\u003e\n\n\u003ctable\u003e\n\n\t\u003cthead\u003e\n\n\t\t\u003ctr\u003e\n\n\t\t\t\u003cth\u003eFeature\u003c\/th\u003e\n\n\t\t\t\u003cth\u003eValue\u003c\/th\u003e\n\n\t\t\u003c\/tr\u003e\n\n\t\u003c\/thead\u003e\n\n\t\u003ctbody\u003e\n\n\t\t\u003ctr\u003e\n\n\t\t\t\u003ctd\u003eContinuous power PRP\u003c\/td\u003e\n\n\t\t\t\u003ctd\u003e30 kVA \/ 24 kW\u003c\/td\u003e\n\n\t\t\u003c\/tr\u003e\n\n\t\t\u003ctr\u003e\n\n\t\t\t\u003ctd\u003eEmergency power LTP\u003c\/td\u003e\n\n\t\t\t\u003ctd\u003e32 kVA \/ 25.6 kW\u003c\/td\u003e\n\n\t\t\u003c\/tr\u003e\n\n\t\t\u003ctr\u003e\n\n\t\t\t\u003ctd\u003eVoltage\u003c\/td\u003e\n\n\t\t\t\u003ctd\u003e400\/230 V\u003c\/td\u003e\n\n\t\t\u003c\/tr\u003e\n\n\t\t\u003ctr\u003e\n\n\t\t\t\u003ctd\u003eFrequency\u003c\/td\u003e\n\n\t\t\t\u003ctd\u003e50 Hz\u003c\/td\u003e\n\n\t\t\u003c\/tr\u003e\n\n\t\t\u003ctr\u003e\n\n\t\t\t\u003ctd\u003eRated current PRP\u003c\/td\u003e\n\n\t\t\t\u003ctd\u003e43 A\u003c\/td\u003e\n\n\t\t\u003c\/tr\u003e\n\n\t\t\u003ctr\u003e\n\n\t\t\t\u003ctd\u003ePower factor\u003c\/td\u003e\n\n\t\t\t\u003ctd\u003ecos φ 0.8\u003c\/td\u003e\n\n\t\t\u003c\/tr\u003e\n\n\t\t\u003ctr\u003e\n\n\t\t\t\u003ctd\u003eSpeed\u003c\/td\u003e\n\n\t\t\t\u003ctd\u003e1,500 rpm\u003c\/td\u003e\n\n\t\t\u003c\/tr\u003e\n\n\t\t\u003ctr\u003e\n\n\t\t\t\u003ctd\u003eEngine\u003c\/td\u003e\n\n\t\t\t\u003ctd\u003eHyundai D18\u003c\/td\u003e\n\n\t\t\u003c\/tr\u003e\n\n\t\t\u003ctr\u003e\n\n\t\t\t\u003ctd\u003eFuel\u003c\/td\u003e\n\n\t\t\t\u003ctd\u003eDiesel\u003c\/td\u003e\n\n\t\t\u003c\/tr\u003e\n\n\t\t\u003ctr\u003e\n\n\t\t\t\u003ctd\u003eEmission standard\u003c\/td\u003e\n\n\t\t\t\u003ctd\u003eEU Stage V\u003c\/td\u003e\n\n\t\t\u003c\/tr\u003e\n\n\t\t\u003ctr\u003e\n\n\t\t\t\u003ctd\u003eGenerator\u003c\/td\u003e\n\n\t\t\t\u003ctd\u003eStamford S0L2-P1\u003c\/td\u003e\n\n\t\t\u003c\/tr\u003e\n\n\t\t\u003ctr\u003e\n\n\t\t\t\u003ctd\u003eVoltage regulation\u003c\/td\u003e\n\n\t\t\t\u003ctd\u003eAVR\u003c\/td\u003e\n\n\t\t\u003c\/tr\u003e\n\n\t\t\u003ctr\u003e\n\n\t\t\t\u003ctd\u003eTank capacity\u003c\/td\u003e\n\n\t\t\t\u003ctd\u003e100 liters\u003c\/td\u003e\n\n\t\t\u003c\/tr\u003e\n\n\t\t\u003ctr\u003e\n\n\t\t\t\u003ctd\u003eRun time at 75% load\u003c\/td\u003e\n\n\t\t\t\u003ctd\u003eapprox. 18 hours\u003c\/td\u003e\n\n\t\t\u003c\/tr\u003e\n\n\t\t\u003ctr\u003e\n\n\t\t\t\u003ctd\u003eSound pressure level at 7 m\u003c\/td\u003e\n\n\t\t\t\u003ctd\u003eapprox. 65 dB(A)\u003c\/td\u003e\n\n\t\t\u003c\/tr\u003e\n\n\t\t\u003ctr\u003e\n\n\t\t\t\u003ctd\u003eDimensions L × W × H\u003c\/td\u003e\n\n\t\t\t\u003ctd\u003e2,220 × 960 × 1,263 mm\u003c\/td\u003e\n\n\t\t\u003c\/tr\u003e\n\n\t\t\u003ctr\u003e\n\n\t\t\t\u003ctd\u003eWeight\u003c\/td\u003e\n\n\t\t\t\u003ctd\u003eapprox. 880 kg\u003c\/td\u003e\n\n\t\t\u003c\/tr\u003e\n\n\t\t\u003ctr\u003e\n\n\t\t\t\u003ctd\u003eElectrical design\u003c\/td\u003e\n\n\t\t\t\u003ctd\u003eDGUV 203-032, IT system\u003c\/td\u003e\n\n\t\t\u003c\/tr\u003e\n\n\t\t\u003ctr\u003e\n\n\t\t\t\u003ctd\u003eControl\u003c\/td\u003e\n\n\t\t\t\u003ctd\u003eComAp AMF25\u003c\/td\u003e\n\n\t\t\u003c\/tr\u003e\n\n\t\u003c\/tbody\u003e\n\n\n\u003c\/table\u003e\n\n\n\u003c\/div\u003e\n\n\n\u003c\/div\u003e\n\n\u003ch3\u003eAdvantages of the GENMAC G30DSS-M5 MA QFIP-DGUV\u003c\/h3\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003eDGUV 203-032 compliant design for construction and assembly sites\u003c\/li\u003e\n\n\t\u003cli\u003e30 kVA continuous power for 400 V and 230 V consumers\u003c\/li\u003e\n\n\t\u003cli\u003eInsulation monitoring in the IT system\u003c\/li\u003e\n\n\t\u003cli\u003eAll-current sensitive residual current circuit breakers Type B\u003c\/li\u003e\n\n\t\u003cli\u003eEU Stage V diesel engine\u003c\/li\u003e\n\n\t\u003cli\u003eUp to 18 hours of run time at 75 percent load\u003c\/li\u003e\n\n\t\u003cli\u003eSoundproofed and weatherproof housing\u003c\/li\u003e\n\n\t\u003cli\u003eRobust construction for construction sites, events, and rental\u003c\/li\u003e\n\n\t\u003cli\u003eForklift pockets and central crane hook\u003c\/li\u003e\n\n\t\u003cli\u003eClear ComAp AMF25 control\u003c\/li\u003e\n\n\t\u003cli\u003eIntegrated drip tray for operating fluids\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n","brand":"GENMAC","offers":[{"title":"Default Title","offer_id":53631773475163,"sku":"SEV-00860","price":25806.55,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0792\/6284\/3227\/files\/STRONG-RENT-G30YS-M5-QFIP-AMF25-RENT-PT3-50-400-3FN.jpg?v=1784673788","url":"https:\/\/sev-stromerzeuger.com\/en\/products\/stromerzeuger-genmac-strong-rent-g30dss-m5-ma-qfip-dguv","provider":"SEV","version":"1.0","type":"link"}