PRAMAC PMD 5000s
PRAMAC PMD 5000s diesel generator with 5.0 kVA maximum LTP output, 4.5 kW COP prime/continuous rating, 186FAD engine, 230 V output, AVR voltage regulation and 165 kg net weight.
Key specifications
Professional power generation
The PRAMAC PMD 5000s can supply suitable electrical loads. Plan connected appliances according to their starting currents, the available continuous power and the electrical safety arrangements.
Features and equipment
Maximum output; do not equate with continuous power.
Prime or continuous rating according to model.
Engine on the listed variant.
Conventional voltage regulation.
Check phase currents and socket ratings.
Check exact variant against manufacturer documentation.
Technical highlights – explained
Maximum output is 5.0 kVA LTP. The listed prime/continuous value is 4.5 kW COP. Consider motor starting currents and load cycle.
Socket configuration: 1 x 230 Volt Schuko 16A IP44; 1 x CEE 230V 32A IP44. Observe the rated current of each outlet.
This is a single-phase unit; respect the individual outlet current limits.
Only operate combustion-engine equipment in suitable outdoor locations. Building backup requires qualified electrical design, transfer switching and suitable protection.
Applications
Check load, connections and protection.
Check load, connections and protection.
Check load, connections and protection.
Technical specifications
Engine and drive
| Engine manufacturer | andere |
|---|---|
| Engine model | 186FAD |
| Fuel | Diesel |
| Starting system | Elektrostart |
| Cooling | Luft |
| Engine speed | 3000 U/min |
| Emission standard | Stage 5 |
Power and alternator
| Maximum LTP kVA | 5.0 |
|---|---|
| Maximum LTP kW | 5.0 |
| Continuous COP kW | 4.5 |
| Voltage regulation | AVR |
| Frequency | 50 Hz |
Sockets and protection
| Sockets | 1 x 230 Volt Schuko 16A IP44; 1 x CEE 230V 32A IP44 |
|---|---|
| IP rating | IP23 |
| Equipment | Voltmeter;Wattmeter;Frequenzanzeige;Kraftstoffanzeige;Ölmangelabschaltung;Radsatz inklusive |
Fuel and operation
| Tank litres | 14,5 |
|---|---|
| Sound at 7 m | 69 |
Dimensions and weight
| Dimensions cm | 91 x 51,8 x 68,2 |
|---|---|
| Net weight kg | 165 |
Further specifications
| Manufacturer number | PR452SXAY00 |
|---|
Frequently asked questions
5.0 kVA LTP.
4.5 kW COP.
Only after qualified electrical assessment, suitable changeover switching and protective measures.
Accessories and options
Confirm model-specific compatibility and availability. Optional equipment is included only when expressly listed in the offer.
PRAMAC generators – advice from SEV
We help with generator selection, safe connections and accessories.
Contact SEV-
Start system
Payment & Security
Payment methods:
Your payment information is processed securely. We do not store any credit card details and do not have access to your credit card details.